ACI 318-99, 318-02, 318-05 Development Lengths
The ACI 318-99, 318-02, and 318-05 codes specify the calculation of basic straight tension development length using equation 12-1 with factors including reinforcement location (Ψt), coating (Ψe), size (Ψs), lightweight concrete (λ), and cover dimension (c), while limiting certain products and ratios, and for standard hooks, equation 12.5.2 modifies the length with factors λ and Ψe, with minimum development lengths set at 12 inches for straight bars and 8db or 6 inches for hooks, and extension length defined as the maximum of 12db or the effective depth per ACI 318 12.10.3.
Basic straight tension development length is calculated using equation 12-1. The following factors are used in this equation:
Ψt = Reinforcement Location Factor
- "Concrete below" is taken as the depth from the rebar center to the bottom of the concrete section
- 1.3 for concrete below ≥ 12 inches
- 1.0 for concrete below < 12 inches
Ψe = Coating Factor
- 1.5 for epoxy coated bars with cover (to center of bar) less than 3db (spacing is not calculated)
- 1.2 for all other epoxy coated bars
- 1.0 for uncoated bars
Note: the product ΨtΨe is never taken as greater than 1.7.
Ψs = Reinforcement Size Factor
- 0.8 for #6 and smaller bars
- 1.0 for #7 and larger bars
λ = Lightweight Aggregate Concrete Factor
- 1.3 for lightweight concrete (wc ≤ 120 pcf)
- 1.0 for normal-weight concrete (wc > 120 pcf)
c = Cover Dimension
Vertical distance from the center of the bar to the nearest concrete surface (spacing is not considered).
The term (c + Ktr)/db is never taken greater than 2.5.
Ktr is conservatively assumed to be zero.
For development of standard hooks, basic tension development length is calculated using equation 12.5.2. The following factors are used to modify this basic length:
- Lightweight aggregate concrete factor, λ, as described above
- The coating factor, Ψe, is taken as 1.2 for epoxy-coated reinforcement
In accordance with ACI 318 12.10.3, the extension length used for this Code is the maximum of 12db or the effective depth of the member, taken as the maximum vertical distance from the center of the reinforcing bar to the farthest concrete surface.
The minimum development length is 12 in for straight bars (12.2.1) and 8db or 6 in for hooks (12.5.1).