Bolts eccentricity in shear plates
The design of single shear plates considers bolt load eccentricity either by following AISC 2005 Manual guidelines—which allow ignoring eccentricity for up to 9 standard-hole bolts, specify calculations with multipliers for 10-12 bolts, and treat eccentricity differently for short-slotted holes and extended plates—or by manually defining eccentricity for bolt groups beyond code coverage, requiring user justification.
There are two options to consider the load eccentricity in the design of single plates.
- 1.
The AISC 2005 Manual states that the eccentricity may be ignored in bolt groups with standard (STD) holes for up to 9 bolts (rows). For connections with 10 to 12 bolts, the eccentricity is calculated as n – 4 (in inches) and a 1.25 multiplier is considered for the C Coefficient. For short-slotted (SSL) holes, eccentricity can be ignored up to n = 12. For any other case, the program considers an eccentricity equal to the distance between the bolt and weld lines. In the case of extended single plates, the shear load is assumed to act at the weld line, at the support web.
- 2.
The other possibility is to define the load eccentricity for the bolt group manually, which allows consideration of more than one column of bolts—a situation not covered by the Code. In this case, it is the user’s responsibility to justify the adopted eccentricity.
References
American Institute of Steel Construction, “Manual of Steel Construction”, 2005.