MicroStation provides several configuration variables—such as MS_PLTCFG_PATH for locating printer driver files, MS_DEFAULT_PLTCFG_FILE to specify default printer configuration files, MS_IMPORT_USINGADOBEPDF to control PDF processing mode, and others like MS_PLT_SYSPRT_PLTFILE, MS_PLT_PDF_PLTFILE, MS_PLT_SYSPRT_DEFAULT_PRINTER, MS_PLT_SYSPRT_DEFAULT_FORM, and MS_PLT_SYSPRT_DEFAULT_TRAY—that collectively manage printer driver settings, default printers, forms, trays, and PDF handling during printing operations without requiring a program restart.
MicroStation includes configuration variables to help set up all aspects of the printing process.
The following configuration variables affect printing operations. Each variable expects a valid value. An invalid value will not override a setting. You do not need to close and restart MicroStation for the configuration variable change to take effect.
Printing Configuration Variables
-
MS_PLTCFG_PATH: Specifies the search path for printer driver configuration (.pltcfg or .plt) files. This path is also used to locate dependent files such as PostScript prolog files, which can be stored anywhere in MS_PLTCFG_PATH. If defined, the first directory in its value is used as the initial directory in the Select Printer Driver Configuration File dialog. Otherwise, the most recently used directory is used.
-
MS_DEFAULT_PLTCFG_FILE: Name of printer driver configuration (.pltcfg or .plt) file that loads, rather than the last one used. This variable replaces the old variable MS_PLOTDLG_DEF_PLTFILE. The old variable is still honored if MS_DEFAULT_PLTCFG_FILE is not defined.
-
MS_IMPORT_USINGADOBEPDF: If set to 1 (default), allows PDF extension to be processed as a raster (ImageDGNFileIO). Useful while printing PDF files. If set to 0, allows PDF extension to be processed as a vector (PdfFileIO). Useful while importing, opening, or attaching PDF files to work with vector data as design elements in a DGN.
-
MS_PLT_SYSPRT_PLTFILE: Name of printer driver configuration (.pltcfg or .plt) file that is used when Windows driver is selected.
-
MS_PLT_PDF_PLTFILE: Name of the printer driver configuration (.pltcfg or .plt) file that is used when the PDF driver is selected.
-
MS_PLT_SYSPRT_DEFAULT_PRINTER: Name of printer that is used when a default system printer opens.
-
MS_PLT_SYSPRT_DEFAULT_FORM: Name of form that is used when a default system printer opens.
-
MS_PLT_SYSPRT_DEFAULT_TRAY: Name of tray that is used when a default system printer opens.
-
MS_PLTFILES: The print output directory specified by this configuration variable is given priority over the most recently used print output directory. If defined, the most recently used directory is always ignored when the Print dialog brings up the Save Print As dialog for saving a print output file.
-
MS_PRINTDEF_PATH: Specifies the search path for print definition (.pset or .ini) files.
-
MS_PENTABLE: Search path for pen tables.
-
MS_PENTABLE_EDITOR: If set to HIDE_MENU_ITEM, removes the print dialog Edit Pen Table menu item.
-
MS_DESIGNSCRIPT_EDITOR: Fully qualified name of a text editor to use when the print dialog's Edit Design Script menu item is activated. For example, set the value to "notepad.exe" (without the quote marks) to use the Windows notepad text editor. If not defined, notepad is used. If set to HIDE_MENU_ITEM, removes the print dialog Edit Design Script menu item.
-
MS_DESIGNSCRIPT_PATH: Search path for design scripts.
-
MS_PLT_PREVIEW_USABLEAREACOLOR: Specifies the color of the usable area rectangle in the preview window.
-
MS_PLT_PREVIEW_PLOTBOXCOLOR: Specifies the color of the print bounding box rectangle in the preview window.
-
MS_PLT_PREVIEW_PLOTFENCECOLOR: Specifies the color of the print fence shape in the preview window.
-
MS_PLTDLG_UNLOADONCLOSE: Controls the load/unload of the Plot dialog on closing.
-
MS_PLTDLG_CLOSE_AFTER_PLOT: If set to 1, the Print dialog closes automatically after a print job is performed successfully.
-
MS_PLT_ENABLE_SCALE_CLIPPING: If set to 0, does not reduce the plot fence or sheet size to accommodate the specified scale factor.
-
MS_PLT_ENABLE_PRESERVE_SCALE: If set to 0, does not preserve the current plot scale when a new view, fence, or paper size is selected.
-
MS_PLT_ENABLE_AUTO_ROTATE: If set to 0, does not manipulate the plot rotation in order to achieve the best fit.
-
MS_PLT_ENABLE_AUTO_ORIENT: If set to 0, does not manipulate the paper orientation in order to achieve the best fit.
-
MS_PLTDLG_AREA_PRIORITY: If set to 1, sheet definitions in the model take priority over the active fence.
-
MS_PLT_FORM_SCALE_PRIORITY: If set to 1, the default form scale is reapplied whenever the paper size changes.
-
MS_PLT_SET_LAYOUT_FROM_SHEET: If set to 0, the Print dialog layout is not automatically set when a sheet definition is loaded and the current print area is Sheet.
-
MS_PLT_SET_PLOT_STYLE_TABLE_FROM_SHEET: If set to 0, plot style tables specified in the sheet definition are not attached to the plot.
-
MS_PLT_MAX_ON_NEW_AREA: If set to 1, the print size is maximized automatically when the print area changes.
-
MS_PLTDLG_AUTO_FIT_VIEW: Controls the setting for the print area mode.
-
MS_PLTDLG_SHOW_BASIC_LAYOUT_CONTROLS: If set to 1, the Print dialog's Rotation field and Mirror option menu are hidden. The orthogonal print Rotation option menu is displayed instead.
-
MS_PLTDLG_ALLOW_FORM_SIZE_EDIT: If set to 1, the size of the selected form may be modified via the Print dialog.
-
MS_PLTDLG_SHOW_PRINT_STATUS: If on, a print status dialog opens when a job is being printed. You can cancel the print job.
-
MS_PLTDLG_THUMBNAIL_PREVIEW_TIMEOUT: Controls how long the thumbnail preview in the Print dialog paints before stopping to allow the rest of the dialog to refresh. The default is 10 seconds.
-
MS_PLTDLG_SHOW_ACCURATE_PREVIEW_ROTATION: If set to 1, the Preview dialog displays the plot in its current rotation.
-
MS_PLTDLG_SET_UNITS_FROM_SHEET: If set to 0, the Print dialog's units are not automatically set from the sheet definition when the current print area is Sheet.
-
MS_PLTDLG_KEEPVIEWFLAGSONFENCECHANGE: When a new fence is placed, controls the setting for resetting or preserving current print attributes.
-
MS_PLOTDLG_DEF_PENTABLE: Defines the default pen table that is loaded.
-
MS_PLTDLG_SETUPSYSPRT_ENABLE_PRINT: Controls the print behavior of the Configure Windows Printer icon.
-
MS_PLTDLG_ENABLE_SAVE_CONFIG: Disables the Print dialog Save Configuration menu items.
-
MS_PLTDLG_DISABLE_PREFERENCES_DIALOG: If set to 1, the Preferences menu item is not displayed on the Settings menu.
-
MS_PLT_SCALE_METHOD: Determines how the print scale displays in the Print dialog.
-
MS_PENTABLE_IMPORTEMPTYSECTIONS: During AutoCAD plot style table imports, ignores pen table sections that have no effect. If set to 1, empty sections are created.
-
MS_PENTABLE_DISABLECOLOR: Controls the color of a disabled section in a pen table; default is medium gray.
-
MS_PENTABLE_SLOTNUM_MATCH_APPLIES_TO_CHILD: Controls how the pen table reference slot number match applies to the parent reference and its children.
-
MS_PENTABLE_SEARCH_LEVEL_LIBRARIES: If set to 0, level libraries are not included when searching for level names defined in the pen table.
-
MS_PENTABLE_IMPORTCTB_NOPENMAP: When importing CTB files, allows the proper color-to-width resymbolization of multi-colored elements.
-
MS_PLTFILE_EDITOR: Controls which editor is used when you select File > Edit Printer Driver Configuration in the Print dialog.
-
MS_PLT_INVERT_WHITE_COLORS: Allows you to override the colors that are automatically inverted from white to black.
-
MS_PLT_ABBREVIATE_BORDER_FILENAME: If set to 0, the filenames included in the plot border text are not abbreviated.
-
MS_PLT_AUTOAREA_RESULT_LIMIT: Defines the maximum number of print definitions to be created when searching for multiple shapes or cells. The default limit is 500.
-
MS_PLT_UPDATE_FIELDS: Controls when fields are updated prior to printing or previewing. If set to 0 or undefined, fields are not updated prior to either printing or previewing. If set to 1, fields are updated prior to printing. If set to 2, fields are updated prior to both printing and previewing.
-
MS_PLT_ENGINE_CMDLINE_ARGS: Specifies custom command line arguments used by Print Organizer when invoking its background process. If this variable is undefined and MS_CONFIG is defined, then the background process is invoked with the command line argument -wc"$(MS_CONFIG)".
-
MS_PLT_ENABLE_VARIABLE_DEFINITION_MODE: If set to 0, Print Organizer creates fixed print definitions. If set to 1, Print Organizer creates variable print definitions.
-
MS_PRINTERLIST_SYSPRINTERS: If set to 0, Windows printer names are not included in the print dialog printer list.
-
MS_PRINTERLIST_VISIBILITY: Controls the behavior of the printer driver configuration file selection list. By default, most .pltcfg files and all .plt files in the MS_PLTCFG_PATH search path are listed. Only .pltcfg files with Visible=0 properties are excluded. The display label property is used to identify .pltcfg files, if defined. Otherwise, the file name is used. Legacy .plt files are always identified by file name.
This variable may be used to control the .pltcfg visibility test. For example, a value of '2-4,6' will result in only .pltcfg files with Visible property values of 2,3,4, and 6 to be included in the list. All .plt files are considered to have a Visible property of 1, as are .pltcfg files that do not explicitly define a Visible property.
There are two reserved values:
- "0": Do not search for printer driver configuration files. Selection can only be performed using a file picker dialog. All files are identified by file name only.
- "-1": Search for printer driver configuration files, but do not read their Display Label or Visible properties. All files are identified by file name only. This setting may be helpful if the time required to build the list is a concern.
-
MS_PRINTORGANIZER_OPEN_DGN_READWRITE: If set to 1, the Print Organizer background process opens design files in read-write mode. Certain print workflows may depend on the design file being writeable.