Bentley Systems

Shear - Single Plate

Single-plate shear connections, welded on both sides to supports and bolted to beams, are preferred for economical and safe skewed beam-to-column or beam-to-girder connections with W shapes or HSS columns, especially when columns are not slender, with design considerations including maximum plate thickness for rotational ductility, bolt spacing and edge distances, and options to account for bolt load eccentricity using defined geometric parameters.

Single-plate connections are always welded to the support on both sides of the plate and bolted to the beam. This connection can be used with W shapes or HSS (circular or rectangular) columns for either beam-to-column (flange or web) or beam-to-girder connections. Both horizontal skew angles and slope vertical angles are accepted. Single plates are the preferred skewed connections for economy and safety.

Preferred Solution in Relation to Through Plates

Single plates should be used for HSS columns when they are not slender due to cost reasons. For rectangular or circular HSS columns, when the column is not slender, the local distortion will be insignificant in reducing the column strength.

Maximum Thickness

The recommended maximum thickness for either the beam or the plate to provide rotational ductility is considered as:

where

db = bolt diameter, in.

When a double column of bolts is used, the foregoing criterion should be applied to both the beam web thickness and the plate.

Additionally, both should satisfy that the Horizontal Edge Distance, Leh ≤ 2×db.

Bolts Eccentricity in Shear Plates

There are two options to consider the load eccentricity in the design of single plates.

Nomenclature

  • L: length
  • b: width
  • sb: beam setback
  • a: distance between the bolt line and the weld line in the single plate. In the case of extended plates, this is the distance between the bolt line and the stiffener edge.
  • DistTop: distance from beam top to single plate top
  • Lev: vertical edge distance
  • Leh: horizontal edge distance
  • s: longitudinal center-to-center spacing (pitch) of bolts
  • nr: number of bolt rows
  • nc: number of bolt columns. By default it is hidden. To enable it, define the load eccentricity for the bolts group as manual method. In beam to column web or beam to girder connections, the bolt columns number can be enabled by setting the plate type as extended.

Note: All connections include a Connections Basic Geometric Dimensions Verification. If any of these verifications is not satisfied then the connection status is changed.

Verified Capacities

  • Weld capacity
  • Bolts capacity

On single plate:

  • Bolt bearing
  • Flexure at bolt line/weld line (at weld line)
  • Shear rupture
  • Tensile rupture
  • Shear yielding
  • Tensile yielding
  • Block shear (for shear and axial loads)
  • Flexural rupture (for extended single plates)
  • Local web buckling (for extended single plates)

On beam:

  • Bolt bearing
  • Shear rupture
  • Tensile rupture
  • Shear yielding
  • Tensile yielding
  • Block shear (for shear and axial loads)
  • Flexural yielding strength (if coped)
  • Flexural rupture (if coped)
  • Local web buckling (if coped)
  • Block shear (if coped)

References

  • Astaneh, A., S.M. Call, and K.M. McMullin, 1989, “Design of Single-Plate Shear Connections”, Engineering Journal, Vol 26, No 1. (1st Qtr.), pp21-32, AISC, Chicago. IL
  • Bull Moose Tube HSS Connections Manual, Bull Moose Tube Company, 1999.
  • Sherman, D. R. and A. Ghorbanpoor, 2002, “Design of Extended Shear Tabs”, Final Report to the American Institute of Steel Construction, AISC, Chicago, IL.
  • Sherman, Donald R., Ales, Joseph M., "The Design of Shear Tabs with Tubular Columns," Master of Engineering Project, University of Wisconsin at Milwaukee, 1990.
  • Thornton, William A., Loescher Michael, AISC - Hollow Structural Sections Connections Manual - American Institute of Steel Construction - 1997.